CALL US

+86 17838360708

Tex415A Slump of Hydraulic Cement Concrete

Tex415A Slump of Hydraulic Cement Concrete

SLUMP OF HYDRAULIC CEMENT CONCRETE

SLUMP OF HYDRAULIC CEMENT CONCRETE TxDOT Designation: Tex-415-A Effective Date: July 2008 1. SCOPE 1.1 This test method describes the procedure for determining

get price

Chapter 17 Tex-415-A, Slump of Portland Cement Concrete

Chapter 17 — Tex-415-A, Slump of Portland Cement Concrete Section 5 — Procedure 400-A, Concrete Test Procedures 17-6 08/1998 – 11/2004 Section 5 Procedure The

get price

SLUMP LOSS OF HYDRAULIC CEMENT CONCRETE

SLUMP LOSS OF HYDRAULIC CEMENT CONCRETE TXDOT DESIGNATION: TEX-430-A CONSTRUCTION DIVISION 2 – 2 LAST REVIEWED: OCTOBER 2014 3.2.2 Ensure that

get price

Test Procedures (400-A Series)

56 行  Air Content of Freshly Mixed Concrete by the Volumetric Method: X: Tex-415-A: Slump of

get price

MINIMUM STANDARDS FOR TESTING AGGREGATE AND

Table 15—Tex-415-A, “Slump of Hydraulic Cement Concrete” Equipment Requirements Procedure Interval (Months) As specified in ASTM C143 As specified in ASTM C143 ASTM

get price

GORRONDONA ENGINEERING SERVICES, INC. 4641 Kennedy ...

Tex-415-A1 Slump of Hydraulic Cement Concrete Tex-416-A1 Air Content of Freshly Mixed Concrete by the Pressure Method Tex-417-A1 Unit Weight, Yield, and Air Content (Gravimetric) of Concrete Tex-418-A Compressive Strength of Cylindrical Concrete Specimens Tex-422-A Measuring Temperature of Freshly Mixed Portland Cement Concrete Tex-450-A ...

get price

Item 421 Hydraulic Cement Concrete

5-Cycle Magnesium Sulfate Soundness,1,2 non-air-entrained concrete, % Max Tex-411-A 25 5-Cycle Magnesium Sulfate Soundness,1,3 air-entrained concrete, % Max 18 Loss by Decantation, % Max Tex-406-A 1.5 1. Recycled crushed hydraulic cement concrete is not subject to 5-cycle magnesium sulfate soundness requirements. 2.

get price

Site Manager Forms

Determining Air Content of Portland Cement Concrete: Tx417: TEX-417-A, Unit Weight, Yield, and Air Content (Gravimetric) of Concrete: ... Testing of Drilled Cores of Portland Cement Concrete: Tx430: Slump Loss of Hydraulic Cement Concrete: Tx431: Pressure Slaking Test of Synthetic Coarse Aggregate: Tx432: Coarse Aggregate Freeze-Thaw: Tx433 ...

get price

Pavement Manual: Concrete Mix Design

The mix design is used to establish the proper proportioning of components (hydraulic cement, aggregates, water, pozzolans, and admixtures) in the mixture to achieve the specified properties. Significant concrete properties are strength, air content, slump, and the coefficient of thermal expansion (COTE). The mix design may be developed for the ...

get price

Cipriano Del Real - Independent Contractor - Self employed ...

Tex-415-A Slump of hydraulic cement concrete Tex-416-A Air content of freshly mixed concrete by the pressure test Tex-418-A Compressive strength of cylindrical concrete specimens Tex

get price

TxDOT Test Description

Tex-415-A Slump of Portland Cement Concrete: C231 Tex-416-A: Air Content of Freshly Mixed Concrete by the Pressure Method C138: Tex-417-A Unit Weight, Yield and Air Content (Gravimetric) of Concrete: C1064 Tex-422-A: Temperature of Freshly Mixed Concrete C31: Tex-447-A Making and Curing Concrete Test Specimens

get price

SELF-CONSOLIDATING GROUT FOR CONCRETE MASONRY -

Standard Test Method for Slump Flow of Self-Consolidating Concrete, ASTM C1611/C1611M-05. ASTM International, Inc., 2005. Grout for Concrete Masonry, TEK 9-4A. National Concrete Masonry Association, 2005. Standard Test Method for Slump of Hydraulic-Cement Concrete, ASTM C143-05a. ASTM International, Inc., 2005.

get price

FIELD AND - dot.state.pa.us

Slump of Hydraulic Cement Concrete 600 T-119 Air Content of Freshly Mixed Concrete by the Chace Indicator 602 T-199 Flexural Strength of Concrete 603 T-97 (Using Simple Beam with Third-Point Loading) Obtaining and Testing Drilled Cores and 606 T-24 Sawed Beams of Concrete Bulk Density (Unit Weight) in Aggregate 609 T-19

get price

Texas Asphalt Pavement Association (TXAPA)

Apr 08, 2020  Table 15—Tex-415-A, “Slump of Hydraulic Cement Concrete”  Equipment Requirements Procedure Interval (Months)   As specified in ASTM C 143 As specified in ASTM C 143 ASTM C 143 See ASTM C 143  Table 16—Tex-416-A, “Air Content of Freshly Mixed Concrete by the Pressure Method”  Equipment Requirements Procedure Interval ...

get price

§ 360S.10. Payment, ITEM NO. 360S - CONCRETE PAVEMENT 9-26 ...

Sep 26, 2012  TEX-415-A Slump of Portland Cement Concrete TEX-416-A Air Content of Freshly-Mixed Concrete by the Pressure Method Tex-418-A ... Hydraulic Cement Concrete Curing Materials and Evaporation Retardants"

get price

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Tex-415-A1 Slump of Hydraulic Cement Concrete Tex-416-A1 Air Content of Freshly Mixed Concrete by the Pressure Method Tex-417-A1 Unit Weight, Yield, and Air Content (Gravimetric) of Concrete Tex-418-A Compressive Strength of Cylindrical Concrete Specimens

get price

Accredited Laboratory

Tex-415-N Slump of Hydraulic Cement Concrete Tex-416-N Air Content of Freshly Mixed Concrete by the Pressure Method Tex-417-N Unit Weight, Yield, and Air Content (Gravimetric,) of Concrete Tex-418-A Compressive Strength of Cylindrical Concrete Specimens

get price

Accredited Laboratory

Tex-415-A1 Slump of Hydraulic Cement Concrete Tex-416-A1 Air Content of Freshly Mixed Concrete by the Pressure Method Tex-417-A1 Unit Weight, Yield, and Air Content (Gravimetric) of Concrete Tex-418-A Compressive Strength of Cylindrical Concrete Specimens Tex-422-A Measuring Temperature of Freshly Mixed Portland Cement Concrete Tex-450-A ...

get price

Item 100 Preparing Right of Way - Leon Valley, Texas

Concrete,” in all concrete when using casing that will be pulled or when placing shafts underwater or under slurry. Use concrete with slump that meets the requirements of Table 2 as determined by Tex-415-A. Table 2 Slump Requirements Placement Type Minimum Acceptable Placement Slump, in. Recommended Design and Placement Slump, in.

get price

SiteManager Forms

Determining Air Content of Portland Cement Concrete: Tx417: TEX-417-A, Unit Weight, Yield, and Air Content (Gravimetric) of Concrete: ... Testing of Drilled Cores of Portland Cement Concrete: Tx430: Slump Loss of Hydraulic Cement Concrete: Tx431: Pressure Slaking Test of Synthetic Coarse Aggregate: Tx432: Coarse Aggregate Freeze-Thaw: Tx433 ...

get price

Texas Asphalt Pavement Association (TXAPA)

Apr 08, 2020  Table 15—Tex-415-A, “Slump of Hydraulic Cement Concrete”  Equipment Requirements Procedure Interval (Months)   As specified in ASTM C 143 As specified in ASTM C 143 ASTM C 143 See ASTM C 143  Table 16—Tex-416-A, “Air Content of Freshly Mixed Concrete by the Pressure Method”  Equipment Requirements Procedure Interval ...

get price

Accredited Laboratory

Tex-415-A1 Slump of Hydraulic Cement Concrete Tex-416-A1 Air Content of Freshly Mixed Concrete by the Pressure Method Tex-417-A1 Unit Weight, Yield, and Air Content (Gravimetric) of Concrete Tex-418-A Compressive Strength of Cylindrical Concrete Specimens Tex-422-A Measuring Temperature of Freshly Mixed Portland Cement Concrete Tex-450-A ...

get price

PORTLAND CEMENT CONCRETE TESTS - tyler

Tex-415-A: Slump of Portland Cement Concrete: Tex-416-A: Air Content of Freshly Mixed Concrete by the Pressure Method: Tex-417-A: Unit Weight, Yield and Air Content (Gravimetric) of Concrete: Tex-418-A: Compressive Strength of Cylindrical Concrete Specimens: Tex-419-A: Compressive Strength of Concrete Using Portions of Beams Broken in Flexure ...

get price

Documento 3. Pliego

“Chemical Admixtures for Concrete,” in all concrete when using casing that will be pulled or when placing shafts underwater or under slurry. Use concrete with slump that meets the requirements of Table 2 as determined by Tex-415-A. Table 2 Slump Requirements Placement Type Minimum Acceptable Placement Slump, in. Recommended Design and Placement

get price

Materials Testing Manual ADOT

Making and Curing Concrete Test Specimens in the Field: C39: Compressive Strength of Cylindrical Concrete Specimens: C78: Flexural Strength of Concrete: C138: Density (Unit Weight), Yield and Air Content (Gravimetric) of Concrete: C143: Slump of Hydraulic-Cement Concrete: C172: Sampling Freshly Mixed Concrete: C173

get price

FIELD AND - dot.state.pa.us

Slump of Hydraulic Cement Concrete 600 T-119 Air Content of Freshly Mixed Concrete by the Chace Indicator 602 T-199 Flexural Strength of Concrete 603 T-97 (Using Simple Beam with Third-Point Loading) Obtaining and Testing Drilled Cores and 606 T-24 Sawed Beams of Concrete Bulk Density (Unit Weight) in Aggregate 609 T-19

get price

GEOSCIENCE ENGINEERING TESTING, INC. CONSTRUCTION ...

ASTM C143/C143M1 Slump of Hydraulic-Cement Concrete ASTM C172/C172M1 Sampling Freshly Mixed Concrete ... Tex-407-A1 Sampling Freshly Mixed Concrete Tex-414-A1 Air Content of Freshly Mixed Concrete by the Volumetric Method Tex-417-A1 Unit Weight, Yield, and Air

get price

Document No: Technical Specifications

“Chemical Admixtures for Concrete,” in all concrete when using casing that will be pulled or when placing shafts underwater or under slurry. Use concrete with slump that meets the requirements of Table 2 as determined by Tex-415-A. Table 2 Slump Requirements Placement Type Minimum Acceptable Placement Slump, in. Recommended Design and Placement

get price

CORROSION MITIGATING CEMENT COMPOSITIONS - SCMT

Slump is a measure of consistency of concrete and often is used as an indication of the water quantity in the plastic concrete. With Portland cement and others, water is consumed during the transportation process, thereby reducing the slump. Contractors often will add water on site to re-obtain the original or desired slump.

get price

(PDF) Mechanical and Permeability Characteristics of Latex ...

Jul 05, 2017  synthetic fiber was approximately 490 times and 41 0–415 times for added ... ove rlay wit h ver y-e arly str engt h la tex-modified concrete. ... Method fo r Slump of Hydraulic-Cement Concrete ...

get price

Mechanical and physical properties of epoxy polymer ...

Feb 01, 2012  Highlights Optimisation of the formulation of epoxy polymer concretes, PC. The optimum polymer content combining the best performances and the lowest cost is about 13%. Cement concrete samples are designed with the same aggregates and the same ratio G/S. Ordinary cement concrete, OCC, has lower mechanical properties compared to polymer concrete. PC exposed to temperatures

get price

US3801338A - Cement additives - Google Patents

US3801338A US3801338DA US3801338A US 3801338 A US3801338 A US 3801338A US 3801338D A US3801338D A US 3801338DA US 3801338 A US3801338 A US 3801338A Authority US United States Prior art keywords additive cement water weight control Prior art date 1972-07-10 Legal status (The legal status is an assumption and is not a legal conclusion.

get price

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 AR ...

Concrete: ASTM C31/C31M1 Making and Curing Concrete Test Specimens in the Field ASTM C39/C39M Compressive Strength of Cylindrical Concrete Specimens ASTM C138/C138M1 Density (Unit Weight), Yield, and Air Content (Gravimetric) of Concrete ASTM C143/C143M1 Slump of Hydraulic-Cement Concrete ASTM C172/C172M1 Sampling Freshly Mixed Concrete